Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Journal of the Korean Association of Oral and Maxillofacial Surgeons ; : 197-203, 2020.
Article | WPRIM | ID: wpr-834712

ABSTRACT

Objectives@#We compared the outcomes of two different doses of FK506 (tacrolimus) for immunosuppression in submandibular salivary gland (SMG) allotransplantation. @*Materials and Methods@#Three SMG allotransplantation groups were established (n=6 per group) as follows: allograft rejection control (Allo-Ctrl), low dose (0.08 mg/kg) of FK506 (FK506-L), and high dose (0.16 mg/kg) of FK506 (FK506-H). Allograft survival and rejection were assessed by clinical observation, interleukin-2 levels as determined by enzyme-linked immunosorbent assay, blood sampling for complete blood count (CBC), and histological evaluation. @*Results@#Body weight and anorexia were higher in the FK506-H group but without a significant difference compared with the FK506-L population. CBC revealed a non-significantly reduced number of changes in the FK506-L group. Four glands in the FK506-H group and two glands in the FK506- L group were viable and functioning post-transplantation. @*Conclusion@#The survival rate of allotransplanted glands was higher in conjunction with the high dose of 0.16 mg/kg of FK506, with no major difference in the side-effect profile when compared with the low dose of 0.08 mg/kg short-term outcomes.

2.
Journal of Dental Rehabilitation and Applied Science ; : 55-63, 2019.
Article in Korean | WPRIM | ID: wpr-764435

ABSTRACT

The aim of this article was to review various methods used to evaluate the accuracy of digital dental models. When evaluating the accuracy of digital models, the errors can be reduced by educating examiners and using artificial landmarks. The accuracy evaluation methods of digital dental models are divided into linear measurement, 2-dimensional cross-sectional analysis, and 3-dimensional best fit measurement. As the technology of scanners develops, many studies have been conducted to compare the accuracy of digital impression and conventional impression. According to improvement of scan technologies and development of 3-dimensional model analysis software, the ability to evaluate the accuracy of digital models is becoming more efficient. In this article, we describe the methods for evaluating the accuracy of a digital model and investigate effective accuracy analysis methods for each situation.


Subject(s)
Cross-Sectional Studies , Models, Dental , Methods
3.
Journal of Dental Rehabilitation and Applied Science ; : 270-279, 2018.
Article in Korean | WPRIM | ID: wpr-739890

ABSTRACT

PURPOSE: The aim of this study was to assess the patients' perception, acceptance, and preference of the difference between a conventional impression and digital impression through questionnaire survey. MATERIALS AND METHODS: Thirteen (6 male, 7 female) subjects who experienced both digital and conventional impression at the same day were enrolled in this study. Conventional impression were taken with polyvinylsiloxane and digital impression were performed using a newly developed intra-oral scanner. Immediately after the two impressions were made, a survey was conducted with the standardized questionnaires consisting of the following three categories; 1) general dental treatment 2) satisfaction of conventional impression 3) satisfaction of digital impression. The perceived source of satisfaction was evaluated using Likert scale. The distribution of the answers was assessed by percentages and statistical analyses were performed with the paired t-test, and P < 0.05 was considered significant. RESULTS: There were significant differences of the overall satisfaction between two impression methods (P < 0.05). Digital impression showed high satisfaction in less shortness of breath and odor to participants compared to conventional impression. The use of an oral scanner resulted in a discomfort of TMJ due to prolonged mouth opening and in lower score of the scanner tip size. CONCLUSION: It was confirmed that the preference for the digital impression using intraoral scanner is higher than the conventional impression. Most survey participants said they would recommend the digital impression to others and said they preferred it for future prosthetic treatment.


Subject(s)
Humans , Male , Dyspnea , Mouth , Odorants , Temporomandibular Joint
4.
Journal of Dental Rehabilitation and Applied Science ; : 280-289, 2018.
Article in Korean | WPRIM | ID: wpr-739889

ABSTRACT

PURPOSE: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). MATERIALS AND METHODS: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III active® long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III active® short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. RESULTS: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). CONCLUSION: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.


Subject(s)
Humans , Computer-Aided Design , Crowns , Dental Implants , Mandible , Molar , Tooth
5.
Maxillofacial Plastic and Reconstructive Surgery ; : 22-2018.
Article in English | WPRIM | ID: wpr-741558

ABSTRACT

BACKGROUND: Cross-facial nerve graft is considered the treatment of choice for facial reanimation in patients with unilateral facial palsy caused by central facial nerve damage. In most cases, a traditional parotidectomy skin incision is used to locate the buccal and zygomatic branches of the facial nerve. METHODS: In this study, cross-facial nerve graft with the sural nerve was planned for three patients with facial palsy through an intraoral approach. RESULTS: An incision was made on the buccal cheek mucosa, and the dissection was performed to locate the buccal branch of the facial nerve. The parotid papillae and parotid duct were used as anatomic landmarks to locate the buccal branch. CONCLUSIONS: The intraoral approach is more advantageous than the conventional extraoral approach because of clear anatomic marker (parotid papilla), invisible postoperative scar, reduced tissue damage from dissection, and reduced operating time.


Subject(s)
Humans , Anatomic Landmarks , Cheek , Cicatrix , Facial Nerve , Facial Paralysis , Mucous Membrane , Skin , Sural Nerve , Transplants
6.
The Journal of Korean Academy of Prosthodontics ; : 188-198, 2018.
Article in Korean | WPRIM | ID: wpr-715999

ABSTRACT

PURPOSE: Recently, according to the development of digital technology, computer aided design/computer aided manufacture (CAD/CAM) system is widely used for fabrication of various dental prostheses in the field of dentistry. This study aims to survey the present state and awareness of CAD/CAM system on domestic dental field, and to supply the advice for the application of the new system. MATERIALS AND METHODS: In this questionnaire survey was conducted for a total of 298 dentists, dental hygienist and dental technicians of the whole country including the dental hospital of Seoul National University for two months from November to December, 2016 through mail. RESULTS: The most important purpose to consider when purchasing a dental CAD/CAM milling machine were the performance of the milling machine (64.43%) and the use of milling machine was the highest with 49.33% of manufacturing for dental prosthesis and customized implant abutment. In addition, more than 60% of respondents answered positively about the purchase of new milling machine if the CAD/CAM milling machine was improved to satisfactory performance. CONCLUSION: This survey results show that the improved CAD/CAM milling machine would be play an important role in the dental industry in preparation for digitization and the 4th industrial revolution.


Subject(s)
Humans , Dental Hygienists , Dental Prosthesis , Dental Technicians , Dentistry , Dentists , Postal Service , Seoul , Surveys and Questionnaires
7.
Journal of Periodontal & Implant Science ; : 312-327, 2017.
Article in English | WPRIM | ID: wpr-187089

ABSTRACT

PURPOSE: This study assessed marginal bone remodeling and soft tissue esthetics after the loading of single bone-level implants in the anterior maxilla. METHODS: An open, single-arm observational clinical trial with 3 years of follow-up was performed, including 22 implants. The patients presented with a single tooth gap in the anterior maxilla (tooth positions 14–24), with natural or restored adjacent teeth. An implant was placed at least 8 weeks post-extraction and healed submerged for 6 weeks. After the second-stage operation, a fixed provisional prosthesis was provided. The final restoration was placed 6 months after the provisional restoration. The time of the provisional crown connection was considered to be the baseline in this study. Esthetic parameters and the marginal bone level were assessed at 6, 12, 24, and 36 months. RESULTS: All implants were well integrated in the bone. A statistically significant increase was found in the mean implant stability quotient between the time of the provisional prosthesis and the time of the final prosthesis. Most implants (95.5%) revealed marginal bone resorption (<0.5 mm), and just 1 implant (4.5%) showed a change of 2.12 mm from baseline to 36 months (mean 0.07±0.48 mm), while the crestal bone level decreased significantly, from 2.34±0.93 mm at baseline to 1.70±1.10 mm at 36 months. The facial gingival margin and papilla were stable and the esthetic scores indicated high patient and dentist satisfaction. CONCLUSIONS: Platform-switching bone-level implants placed in maxillary single-tooth gaps resulted in successful osseointegration with minimal marginal bone resorption. The peri-implant soft tissue was also esthetically satisfying and stable.


Subject(s)
Humans , Alveolar Bone Loss , Bone Remodeling , Bone Resorption , Crowns , Dental Implants , Dentists , Esthetics , Follow-Up Studies , Maxilla , Observational Study , Osseointegration , Prostheses and Implants , Tooth
SELECTION OF CITATIONS
SEARCH DETAIL